Application of low-pressure differential mass flow controllers in heat treatment processes

2025-07-08

Word Size

Project Background

This client is a leading enterprise in the heat treatment industry. When facing challenges such as improving equipment automation performance and increasing the domestication rate of equipment, they urgently needed a customized gas mass flow controller/flow meter that meets process requirements. The client proactively contacted AccuFlow Technology seeking an efficient solution.

 

Customer Needs

In a certain heat treatment process, natural gas needs to stably output a maximum flow rate of 30Nm³/h (500L/min) under low inlet pressure (6KPa). The customer originally used a "flow meter + control valve" combination scheme, but the following problems existed: 

1. Slow system response speed, difficult to meet rapid adjustment needs;

2. Separation of flow measurement and control leads to reduced accuracy;

3. Large installation space requirements, complex pipeline connections, increasing construction difficulty;

4. High maintenance cost, requiring separate calibration of the flow meter and valve.

5. Simultaneously equipped with analog signals and 485Modbus digital communication, it can be controlled by PLC, computer and other host computers.

 

Solution

 

AccuFlow Technology In response to customer needs, considering the equipment application scenario, medium characteristics, signal output requirements, especially the core elements of gas working pressure, the ACU20FDR-BC low pressure difference mass flow controller is recommended. The flow meter and valve are integrated in design, through customized valve and built-in PID adjustment function to ensure rapid and stable automated flow control while maintaining low pressure loss; Accuracy can reach ±0.5%FS ; The high-flow electromagnetic valve is equipped to operate stably under low pressure difference, achieving flow control under near atmospheric pressure conditions and shortening the system response time; that is, under a pressure difference of 6Kpa, the natural gas flow can be accurately and stably controlled to reach 30Nm³/h (500L/min), fully meeting the process requirements of outputting a large flow rate under low-pressure conditions in the heat treatment industry.

The basic operating conditions are as follows:

Technical Indicators

Parameter Details

Controlled Medium

Natural Gas

Measurement Range

0-30Nm³/h (500L/min)

Pressure

Inlet pressure approximately 6Kpa, full-scale pressure difference: 6Kpa

Analog Signal

4-20mA

Communication Method

RS485 Modbus

Supply Voltage

24V DC

Interface Type

RC one-inch threaded interface

Advantages of the Solution

The ACU20FDR-BC low pressure difference mass flow controller/flow meter solves customer pain points with its core advantages

ACU20DR-BC

1. Thermal principle, fast response, high accuracy

2. Tubular flow diversion, not easy to block, easy maintenance

3. Suitable for various low-pressure and high-pressure pipelines, strong compatibility

4. Short preheating time, small zero drift, stable and reliable operation

5. Digital input/output, can use flow computer to control or display flow

 

 

ACU20FDR-BC low pressure difference mass flow controller/flow meter is not only suitable for the heat treatment industry, but can also be widely used in industrial manufacturing, petrochemicals, environmental protection, various instrument analysis and other fields, meeting the needs of various scenarios and conditions, providing customers with accurate and stable flow measurement and control solutions, from equipment selection and parameter matching to system integration, providing one-stop measurement and control solutions to help customers achieve intelligent production and maximize energy efficiency.


Related Products

ACU10FA


The ACU10FA analog-type mass flow controller features fast response and high precision. It offers a wide control range, with a flow rate capability spanning from 5 SCCM to 30 SLM, and can accurately measure and regulate flows as low as 1 SCCM—making it ideal for controlling even the tiniest gas flows.

ACU10FD


The ACU10FD digital mass flow controller consists of a mass flow sensor, laminar flow separator, flow controller regulating valve, and amplification control circuit. It features digital signal input and output, offering advantages such as short preheating time, minimal zero drift, and high reliability.

ACU10FDR


The ACU10FDR low-pressure-drop gas mass flow controller is equipped with a proprietary high-flow electromagnetic valve, making it ideal for controlling mass flow even when system pressure is nearly unavailable. Its minimal pressure differential ensures the least possible impact on the system, enabling precise flow control under near-atmospheric conditions while significantly reducing system response time. We can customize the valve and PID control features based on your specific application parameters, guaranteeing fast, stable performance with minimized pressure loss.

ACU10FC


The ACU10FC differential-pressure mass flow controller employs a differential-pressure-based mass measurement principle that features no thermal drift and zero response lag. It can simultaneously display and output parameters such as instantaneous flow rate, totalized flow, pressure, and temperature. When control functionality is required, an electromagnetic proportional control valve can be added, along with built-in PID regulation capabilities. Unlike thermal mass flow meters, the ACU10FC eliminates any additional "specific heat capacity" error when using gas conversion factors. As a result, even if the gas being measured differs from the calibration gas used at the factory, the measurement accuracy remains unaffected.

ACU10P


The ACU10P series pressure controllers/pressure gauges feature a straight-through design, with measurement ranges from 100 kPa to 10 MPa (both absolute and gauge pressures are supported). Additionally, differential pressure transmitters are also available.