Laminar Flow Differential Pressure Mass Flow Controller: Enabling Precise Flow Measurement and Control

2026-07-03

Word Size

The core logic of the laminar‑flow differential‑pressure mass flow controller is as follows: gas enters through the inlet and passes through a specially designed laminar‑flow element, which uses precision flow channels to transform disordered turbulent flow into a stable laminar flow, thereby creating ideal conditions for measurement. A built‑in high‑sensitivity differential pressure sensor continuously measures the pressure drop across the element and, via a calibrated algorithm, converts this reading into a flow rate. Meanwhile, a temperature sensor dynamically compensates for temperature‑induced variations, eliminating measurement bias. Based on this principle, the laminar‑flow differential‑pressure mass flow controller delivers excellent accuracy and repeatability across its entire range, is not limited by the gas’s specific heat capacity, exhibits broad media compatibility, and requires no heating unit. Coupled with a flow valve that adjusts its opening in response to the control signal, it forms a closed loop—“measurement–calculation–control”—enabling precise, fast‑response operation.

Beijing AccuFlow Technology Co., Ltd. (hereinafter referred to as “ACCU”) Having cultivated this technology for many years, the company has launched its differential-pressure series ( ACU10FC/ACU20FC/ACU30FC Mass Flow Controller/Flow Meter ) Building on its traditional strengths, it has further enhanced intelligence and ease of use. Among them, ACU30FC Featuring a compact mechanical design, it occupies minimal space, making it easy to integrate into narrow pipelines or retrofit existing systems. Its measurement range spans from ultra‑low to high flow rates, with consistent accuracy across the entire span. At its core, it employs a differential pressure principle that exhibits no thermal drift and zero response lag, fundamentally eliminating “specific heat capacity”‑related errors. When switching between gases, no recalibration is required, and it comes preloaded with multiple gas databases, enabling precise measurements with a single button press. Additionally, it supports real‑time display and output of multiple parameters—including instantaneous flow, cumulative flow, pressure, and temperature—while featuring a large, high‑resolution screen that clearly presents flow rate, differential pressure, and other key data in an intuitive, user‑friendly interface.

 

At present, the ACU differential-pressure series products are widely used in the following fields:

1. Industrial production: carrier gas, protective gas, and online metering of low-pressure process fluids in the chemical industry.

2. Environmental Protection and Atmospheric Monitoring: Monitoring and controlling environmental parameters such as exhaust gas emissions and air quality.

3. Energy Management: In pipeline systems for natural gas, liquefied petroleum gas, and other energy sectors, measure and control gas flow rates.

4. Scientific Experiments: Precise fluid experiments and analyses conducted in a laboratory setting.

5. Medical Equipment: In medical devices, it is used to control and monitor fluid delivery, gas therapy, and other processes.

6. Laboratory applications: gas mixing, microfluidic experiments, and ventilation airflow monitoring.

It is also widely used in numerous industries, including semiconductors and heat treatment.

 

Amid the twin waves of intelligent manufacturing and domestic substitution, ACCU leverages its robust measurement and control technologies, consistent product quality, and flexible customization capabilities to deliver cost-effective, highly reliable flow‑measurement and control solutions for China’s high‑end manufacturing sector, ensuring that every process runs smoothly and with unwavering precision.


Related Products

ACU20FD Normally Open Valve Series


The ACU20FD digital mass flow meter consists of a mass flow sensor, a laminar flow splitter, a flow-control regulating valve, and an amplification and control circuit. It features digital signal input and output, short warm-up time, minimal zero drift, and high reliability.

ACU20PH Series


The ACU20PH series comes standard with a piezoelectric diaphragm‑type pressure sensor and a digital circuit board, delivering high‑accuracy, stable, and reliable pressure measurement and control. This basic digital PC board incorporates all the essential functions required for measurement and control. In addition to the standard RS485 output signal, the ACU20PH also offers analog I/O signals.

ACU10FA Series


The ACU10FA analog mass flow controller features fast response and high accuracy. It offers a wide control range, spanning from 5 SCCM to 30 SLM, and can measure and regulate flow rates as low as 1 SCCM, making it suitable for controlling very small flow rates.

ACU10FD Series


The ACU10FD digital mass flow controller comprises a mass flow sensor, a laminar flow element, a flow‑control regulating valve, and an amplification control circuit. It features digital signal input and output, short warm‑up time, low zero drift, and high reliability.

ACU10FDR


The ACU10FDR low-pressure-drop gas mass flow controller is equipped with a proprietary high-flow electromagnetic valve, making it ideal for controlling mass flow even when system pressure is nearly unavailable. Its minimal pressure differential ensures the least possible impact on the system, enabling precise flow control under near-atmospheric conditions while significantly reducing system response time. We can customize the valve and PID control features based on your specific application parameters, guaranteeing fast, stable performance with minimized pressure loss.