Product Center

ACU10F-G
Category:
Product attachment:
Product Description
- Product Description
-
I. Product Overview
The ACU10F-G wireless flow meter uses multi-parameter measurement technology. One instrument can replace four instruments: differential pressure, pressure, flow, and totalizer, saving customers procurement and installation costs. The integrated flow meter uses full-parameter dynamic compensation technology to improve the instrument's accuracy and rangeability; full-scale static pressure compensation technology improves the accuracy of the flow device operation; it can be calibrated with the flow element, and the calibration accuracy is better than that of the split type; the functions are specialized and integrated;
The ACU10F-G wireless flow meter adds wireless remote transmission functionality based on ACUFT.
Different flow elements can be selected for the ACU10F-G wireless flow meter according to the needs (see the selection table - flow element type). The corresponding technical parameters will also be slightly different. Please refer to the integrated multi-variable orifice plate flow meter [P], integrated multi-variable V-cone mass flow meter [M], and integrated multi-variable V-bar mass flow meter [B]. Please consult the manufacturer if anything is unclear.
II. Industry Applications
The ACU10F-G wireless flow meter is used for the measurement of gas, liquid, and steam in the petroleum, chemical, power, pharmaceutical, food, papermaking, water treatment, metallurgy, cement, and glass industries.
III. Technical Parameters (Related to the flow element type)
1. [P] Orifice plate, nozzle, Venturi, etc., standard flow elements that do not require in-situ calibration
Accuracy Grade Differential pressure: 0.075% Pressure: 0.25% Temperature: 0.5℃ Flow accuracy: 0.5~2.5% Applicable Medium Suitable for various gases, low-viscosity liquids, and steam measurement Pressure Range Differential pressure: 0~21MPa Ambient Temperature With LCD: -20~70℃ Without LCD: -40~85℃ Pipe Diameter DN50~DN300 Rangeability ≥8:1 Power Supply 24VDC Straight Pipe Section Requirements 5D upstream and 2D downstream (consult the factory if the straight pipe section is insufficient) Material Compatibility Stainless steel, Hastelloy, and tantalum are optional Enclosure Protection IP67 Electromagnetic Shielding IEC61000-4-2-5 Installation Method Integrated and split types are optional Explosion-proof Type Intrinsic safety and explosion-proof types are optional Calibration Method Water calibration or gas calibration 2. [M] V-type, wedge-type, etc., flow elements that require in-situ calibration
Accuracy Grade Differential pressure: 0.075% Pressure: 0.25% Temperature: 0.5℃ Flow accuracy: 0.3~0.5% Applicable Medium Suitable for liquids, steam, and gases Pressure Range 0.65~21MPa (contact us for pressures exceeding this range) Ambient Temperature With LCD: -20~70℃ Without LCD: -40~85℃ Operating Temperature -60~550℃ Pipe Diameter DN50~DN500 Rangeability ≥15:1 Power Supply 24VDC Straight Pipe Section Requirements 3D upstream and 1D downstream (consult the factory if the straight pipe section is insufficient) Material Compatibility Stainless steel, Hastelloy, and tantalum are optional Enclosure Protection IP67 Electromagnetic Shielding IEC61000-4-2-5 Installation Method Integrated and split types are optional Explosion-proof Type Intrinsic safety and explosion-proof types are optional Calibration Method Water calibration or gas calibration 3. [B] Various insertion-type uniform tubes and Pitot tubes
Accuracy Grade Differential pressure: 0.075% Pressure: 0.25% Temperature: 0.5℃ Flow accuracy: 0.5~2% Applicable Medium Suitable for various gases, steam, and low-viscosity liquids Pressure Range 0~21MPA Ambient Temperature With LCD: -20~70℃ Without LCD: -40~85℃ Pipe Diameter DN15~DN12000 (circular pipes), side length 200~4000 (square pipes) Rangeability ≥10:1 Power Supply 24VDC Straight Pipe Section Requirements 10D upstream and 3D downstream (consult the factory if the straight pipe section is insufficient) Material Compatibility Stainless steel, Hastelloy, and tantalum are optional Enclosure Protection IP67 Electromagnetic Shielding IEC61000-4-2-5 Installation Method Integrated and split types are optional Explosion-proof Type Intrinsic safety and explosion-proof types are optional Calibration Method Water calibration or gas calibration